﻿<?xml version="1.0" encoding="utf-8"?><?xml-stylesheet type="text/xsl" href="http://as-interface.net/Style/Layout/RSSWeb.xsl" media="screen"?><rss version="2.0" xmlns:msxsl="urn:schemas-microsoft-com:xslt" xmlns:asi="urn:as-interface.net" xmlns:scr="urn:as-interface.net:scr" xmlns:ctrl="urn:as-interface.net:ctrl" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xhtml="http://www.w3.org/1999/xhtml" xmlns:req="request" xmlns:res="result" xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"><channel><title>AS-Interface Innovations</title><link>http://as-interface.net/Products/Innovations</link><description>Latest Innovations</description><language>EN</language><copyright>Copyright 2001-2012 © AS-International Association.</copyright><docs>http://blogs.law.harvard.edu/tech/rss</docs><image><url>http://as-interface.net/Images/LogoSmall.gif</url><title>AS-Interface</title><link>http://as-interface.net/</link><width>144</width><height>92</height></image><item><title>ASI4U-F</title><description><![CDATA[<table border="0" width="100%" cellspacing="0" cellpadding="0" class="Std" style="margin-top: 8px;font-size:8pt" xmlns="http://www.w3.org/1999/xhtml"><tr valign="top"><td><a href="http://as-interface.net/EN/Products/Image/19085FB1-7224-41BA-82FF-8AB46FD3E215"><img alt="ASI4U-F Universal Actuator-Sensor Interface IC for -40°C" border="1" src="http://as-interface.net/Products/Image/19085FB1-7224-41BA-82FF-8AB46FD3E215?MaxWidth=250&amp;MaxHeight=360&amp;Format=JPG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Manufacturer:</h3><a href="http://as-interface.net/EN/Branch/547A0B8A-6D42-4DE5-92EA-620F0B6B0FE4"><img alt="ZMD AG Logo" border="0" vspace="5" src="http://as-interface.net/Company/Logo/ZM?MaxWidth=180&amp;MaxHeight=110&amp;Format=PNG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Contact:</h3><a href="http://as-interface.net/EN/Contact/35774EC2-7024-4A36-BA38-01ACE84E1942">Mr. Gerd Thierfelder </a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Category:</h3><a href="http://as-interface.net/EN/Products/Innovations/List/ACC">Accessories and Other</a><br />Integrated Circuits<br /><br /><img alt="ZMASI4UF" border="0" vspace="5" src="http://as-interface.net/DataMatrix/ZMASI4UF?Size=4"></img></td><td style="padding-left:15px"><h2 class="NoMargin" style="font-family: verdana;font-size: 8pt;color: #000000;font-weight: bold;background-color: #dedede;margin-top: 0px;padding:4px;padding-left:7px;margin-bottom: 9px;margin-left: 0px;margin-right: 0px;text-decoration: none;">ASI4U-F</h2>Universal Actuator-Sensor Interface IC for -40°C<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Order No.:</h3>see ZMDI AS-i IC Ordering Guide<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Certification by:</h3>AS-international Association<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Certification No:</h3>65901<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Description:</h3>The “F” version of the ASI4U is functionally and pin-compatible with ZMDI’s ASI4U family in SSOP28 package and it conforms to the AS-Interface Specification v3.0. It is perfect for extremely cold and harsh environments for process and factory automation applications and can easily be used at ambient temperatures ranging from -40°C to +85°C, which minimizes extensive and costly module tests. The ASI4U-F is also supported by the ZMDI AS-Interface development tools. 

The ASI4U-F (“ASI for You”) is AS-International certified; it is a highly integrated CMOS IC. Implemented in the IC are features from the AS-Interface specification 3.0, such as a 4I/4O mode and a synchronous data IO mode. Extensive configuration and filtering can be carried out, which is saved on the integrated circuit’s internal EEPROM. Further highlights include the isolated transmitter, which allows high module symmetries in electrically intensive applications through component economisation, an integrated electronic inductor with a maximum power of 55mA, as well as an integrated safety mode for use with safety related applications.<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Specification:</h3>V3.0<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Product Link:</h3><a href="http://www.zmdi.com/products/as-interface/" target="_blank" alt="http://www.zmdi.com/products/as-interface/">www.zmdi.com/products/as-interface/</a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Documents:</h3><p><a href="/Products/Datasheet/19085FB1-7224-41BA-82FF-8AB46FD3E215" title="Datasheet.pdf"><img src="/Images/DocTypes/pdfdoc.gif" width="16" height="16" align="absmiddle" border="0" hspace="3" vspace="1" alt="PDF" />Datasheet.pdf</a></p><p><a href="/Products/Brochure/19085FB1-7224-41BA-82FF-8AB46FD3E215" title="Brochure.pdf"><img src="/Images/DocTypes/pdfdoc.gif" width="16" height="16" align="absmiddle" border="0" hspace="3" vspace="1" alt="PDF" />Brochure.pdf</a></p></td></tr></table>]]></description><category>Innovations</category><link>http://as-interface.net/EN/Products/Innovations/19085FB1-7224-41BA-82FF-8AB46FD3E215</link><guid isPermaLink="true">http://as-interface.net/EN/Products/Innovations/19085FB1-7224-41BA-82FF-8AB46FD3E215</guid><dc:date>2012-05-08T17:02:48.32</dc:date><pubDate>2012-05-08T17:02:48.32</pubDate><author>ZMD AG</author><dc:creator>ZMD AG</dc:creator></item><item><title>Emergency Stop Switch</title><description><![CDATA[<table border="0" width="100%" cellspacing="0" cellpadding="0" class="Std" style="margin-top: 8px;font-size:8pt" xmlns="http://www.w3.org/1999/xhtml"><tr valign="top"><td><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Manufacturer:</h3><a href="http://as-interface.net/EN/Branch/A6C8A9F4-2B2E-4DB0-9B2B-C0285D2D8A01"><img alt="Idec Elektrotechnik GmbH Logo" border="0" vspace="5" src="http://as-interface.net/Company/Logo/ID?MaxWidth=180&amp;MaxHeight=110&amp;Format=PNG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Contact:</h3><a href="http://as-interface.net/EN/Contact/7DD82626-5AC4-4742-AF01-A637019099E1">Mr. Günther Schmidt </a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Category:</h3><a href="http://as-interface.net/EN/Products/Innovations/List/SAFTY">Safety At Work</a><br />Emergency Stop / Command Device</td><td style="padding-left:15px"><h2 class="NoMargin" style="font-family: verdana;font-size: 8pt;color: #000000;font-weight: bold;background-color: #dedede;margin-top: 0px;padding:4px;padding-left:7px;margin-bottom: 9px;margin-left: 0px;margin-right: 0px;text-decoration: none;">Emergency Stop Switch</h2><a href="http://as-interface.net/EN/System/Safety"><img src="http://as-interface.net/Images/SaWSmall.gif" align="right" alt="Safety at Work Product" border="0"></img></a>XA-series, XW series<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Order No.:</h3>XA1E + XW1E<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Description:</h3>Emergency stop switch with safety slave functions can be connected to the AS-Interface Safety at Work network.
Complies with IEC 61508 SIL3
Available in 16mm, 22mm, illuminated & non-illuminated<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Product Link:</h3><a href="http://www.idec.de/produkte/-broschueren/sicherheitsprodukte/AS-Interface-E-Stop_EP1143-0.pdf" target="_blank" alt="http://www.idec.de/produkte/-broschueren/sicherheitsprodukte/AS-Interface-E-Stop_EP1143-0.pdf">www.idec.de/produkte/-broschueren/sicherheitsprodu…</a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Documents:</h3><p><a href="/Products/Datasheet/E3209BCA-A9FF-45F4-BB59-F4FF02EA0207" title="Datasheet.pdf"><img src="/Images/DocTypes/pdfdoc.gif" width="16" height="16" align="absmiddle" border="0" hspace="3" vspace="1" alt="PDF" />Datasheet.pdf</a></p></td></tr></table>]]></description><category>Innovations</category><link>http://as-interface.net/EN/Products/Innovations/E3209BCA-A9FF-45F4-BB59-F4FF02EA0207</link><guid isPermaLink="true">http://as-interface.net/EN/Products/Innovations/E3209BCA-A9FF-45F4-BB59-F4FF02EA0207</guid><dc:date>2012-05-08T16:07:35.677</dc:date><pubDate>2012-05-08T16:07:35.677</pubDate><author>Idec Elektrotechnik GmbH</author><dc:creator>Idec Elektrotechnik GmbH</dc:creator></item><item><title>MSS ASIsafe basic (2 ... 10 enabling circuits)</title><description><![CDATA[<table border="0" width="100%" cellspacing="0" cellpadding="0" class="Std" style="margin-top: 8px;font-size:8pt" xmlns="http://www.w3.org/1999/xhtml"><tr valign="top"><td><a href="http://as-interface.net/EN/Products/Image/9171B823-A4AF-474E-B7E2-4D9C084BE2A3"><img alt="MSS ASIsafe basic (2 ... 10 enabling circuits) Central Module ASIsafe basic" border="1" src="http://as-interface.net/Products/Image/9171B823-A4AF-474E-B7E2-4D9C084BE2A3?MaxWidth=250&amp;MaxHeight=360&amp;Format=JPG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Manufacturer:</h3><a href="http://as-interface.net/EN/Branch/441E1EA1-E351-402A-8186-378EF4FEF8C2"><img alt="Siemens AG, Industry Sector, Control Components and Systems Engineering Logo" border="0" vspace="5" src="http://as-interface.net/Company/Logo/SI?MaxWidth=180&amp;MaxHeight=110&amp;Format=PNG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Category:</h3><a href="http://as-interface.net/EN/Products/Innovations/List/SAFTY">Safety At Work</a><br />Safety Monitor / Safety PLC</td><td style="padding-left:15px"><h2 class="NoMargin" style="font-family: verdana;font-size: 8pt;color: #000000;font-weight: bold;background-color: #dedede;margin-top: 0px;padding:4px;padding-left:7px;margin-bottom: 9px;margin-left: 0px;margin-right: 0px;text-decoration: none;">MSS ASIsafe basic (2 ... 10 enabling circuits)</h2><a href="http://as-interface.net/EN/System/Safety"><img src="http://as-interface.net/Images/SaWSmall.gif" align="right" alt="Safety at Work Product" border="0"></img></a>Central Module ASIsafe basic<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Order No.:</h3>3RK3<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Certification by:</h3>TÜV Nord<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Description:</h3>The safety monitors from Siemens are a central component of safety-related applications based on ASIsafe, and they are an established force in the market. Consistent further development of this technology has now reached yet another milestone with the new ASIsafe basic central unit of the SIRIUS 3RK3 Modular Safety System (MSS). The MSS SIRIUS 3RK3 is a modular safety system. Like the safety monitors, it detects safety sensors on the AS-i bus, and disconnects actuators safely via parameterizable safety logic. However, it is the quantity structure of the MSS that adds value to today's safety monitors. The MSS ASIsafe basic now comes into play in small, medium and large applications where previously two or more safety monitors had to be used. <br>
<br>
The MSS ASIsafe basic from Siemens corresponds to many safety monitors in a single device. It can be expanded up to 10 independent two-channel enabling circuits via the internal safe device bus using additional inputs and outputs. This makes it the world's first modularly expandable safety monitor!<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Specification:</h3>V3.0<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Special Features:</h3>- A modular and scaleable safety system based on AS-Interface/ASIsafe <br> 
- 2 to 10 independent enabling circuits (2-channel) up to PL e in acc. with EN 13849-1, SIL3 in acc. with IEC 62061<br>
- Control or disconnection of up to 8 independent shutdown groups distributed via ASIsafe <br> 
- 1 safety-related and 6 standard inputs on the central unit, e.g. for central EMERGENCY STOP <br>
- 2 safety-related outputs on the central unit (up to 2A) <br>
- Fail-safe data exchange between several MSS possible via ASIsafe <br>
- Graphic parameter assignment of the safe logic with the new MSS ES parameterization software by Drag and Drop <br> 
- Muting (2-sensor, 4-sensor, 4-sensor sequential) <br>
- Memory module for device parameters <br> 
<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Product Link:</h3><a href="http://www.siemens.com/sirius-mss" target="_blank" alt="http://www.siemens.com/sirius-mss">www.siemens.com/sirius-mss</a></td></tr></table>]]></description><category>Innovations</category><link>http://as-interface.net/EN/Products/Innovations/9171B823-A4AF-474E-B7E2-4D9C084BE2A3</link><guid isPermaLink="true">http://as-interface.net/EN/Products/Innovations/9171B823-A4AF-474E-B7E2-4D9C084BE2A3</guid><dc:date>2012-04-16T09:32:46.183</dc:date><pubDate>2012-04-16T09:32:46.183</pubDate><author>Siemens AG, Industry Sector, Control Components and Systems Engineering</author><dc:creator>Siemens AG, Industry Sector, Control Components and Systems Engineering</dc:creator></item><item><title>AS-i Safety monitor, 2 channels</title><description><![CDATA[<table border="0" width="100%" cellspacing="0" cellpadding="0" class="Std" style="margin-top: 8px;font-size:8pt" xmlns="http://www.w3.org/1999/xhtml"><tr valign="top"><td><a href="http://as-interface.net/EN/Products/Image/54743699-8303-4C1A-BAAE-83A62703AA42"><img alt="AS-i Safety monitor, 2 channels With semi-conductor outputs" border="1" src="http://as-interface.net/Products/Image/54743699-8303-4C1A-BAAE-83A62703AA42?MaxWidth=250&amp;MaxHeight=360&amp;Format=JPG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Manufacturer:</h3><a href="http://as-interface.net/EN/Branch/273B3C50-2E0D-4C7F-8868-311CA8B5D29B"><img alt="ifm electronic gmbh Logo" border="0" vspace="5" src="http://as-interface.net/Company/Logo/IF?MaxWidth=180&amp;MaxHeight=110&amp;Format=PNG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Contact:</h3><a href="http://as-interface.net/EN/Contact/6DC06092-9A4C-47F1-BBEC-520C13E41935">Mr. Hansjörg Hopp </a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Category:</h3><a href="http://as-interface.net/EN/Products/Innovations/List/SAFTY">Safety At Work</a><br />Safety Monitor / Safety PLC<br /><br /><img alt="IFAC041S" border="0" vspace="5" src="http://as-interface.net/DataMatrix/IFAC041S?Size=4"></img></td><td style="padding-left:15px"><h2 class="NoMargin" style="font-family: verdana;font-size: 8pt;color: #000000;font-weight: bold;background-color: #dedede;margin-top: 0px;padding:4px;padding-left:7px;margin-bottom: 9px;margin-left: 0px;margin-right: 0px;text-decoration: none;">AS-i Safety monitor, 2 channels</h2><a href="http://as-interface.net/EN/System/Safety"><img src="http://as-interface.net/Images/SaWSmall.gif" align="right" alt="Safety at Work Product" border="0"></img></a>With semi-conductor outputs<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Order No.:</h3>AC041S<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Description:</h3>AS-i safety made easy<br>
AS-i safety monitor allows parameter setting via USB interface.<br>
<font color=#FF9900><li><font color=black>4 safe inputs or 8 standard inputs/outputs locally.
<font color=#FF9900><li><font color=black>2 safe electronic outputs locally, 6 triggerable outputs in the field.
<font color=#FF9900><li><font color=black>USB 2.0 interface for clear configuration and diagnosis using the PC.
<font color=#FF9900><li><font color=black>Saving of data on chip card for an easy exchange of units.
<font color=#FF9900><li><font color=black>Certification to EN 62061/SIL3, IEC 61508/SIL3 and EN ISO 13849-1/PLe.<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Special Features:</h3>The new AS-i safety monitor processes up to four safe
inputs or eight standard inputs/outputs<br>locally and up
to 31 safe slaves in the AS-i system.<br>The AS-i safety
monitor is equipped with a USB interface and a chip card
for an easy exchange of units.<br>
The user-friendly configuration and diagnostic software
ASIMON V3.0 G2 enables clear<br>and quick assignment
and logical combination of the safety-related bus components<br>
in the tried-and-tested function block representation under Windows.<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Product Link:</h3><a href="http://www.ifm.com/products/uk/ds/AC041S.htm" target="_blank" alt="http://www.ifm.com/products/uk/ds/AC041S.htm">www.ifm.com/products/uk/ds/AC041S.htm</a></td></tr></table>]]></description><category>Innovations</category><link>http://as-interface.net/EN/Products/Innovations/54743699-8303-4C1A-BAAE-83A62703AA42</link><guid isPermaLink="true">http://as-interface.net/EN/Products/Innovations/54743699-8303-4C1A-BAAE-83A62703AA42</guid><dc:date>2012-04-03T13:46:05.54</dc:date><pubDate>2012-04-03T13:46:05.54</pubDate><author>ifm electronic gmbh</author><dc:creator>ifm electronic gmbh</dc:creator></item><item><title>Inverter SK 225E / SK 235E</title><description><![CDATA[<table border="0" width="100%" cellspacing="0" cellpadding="0" class="Std" style="margin-top: 8px;font-size:8pt" xmlns="http://www.w3.org/1999/xhtml"><tr valign="top"><td><a href="http://as-interface.net/EN/Products/Image/3EBA6B1D-A702-42FA-8545-40F2046A26D7"><img alt="Inverter SK 225E / SK 235E SK 200E motor-mounted frequency inverters offer increased flexibility for decentralised control " border="1" src="http://as-interface.net/Products/Image/3EBA6B1D-A702-42FA-8545-40F2046A26D7?MaxWidth=250&amp;MaxHeight=360&amp;Format=JPG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Manufacturer:</h3><a href="http://as-interface.net/EN/Branch/762FADE5-E7A7-4D51-BFB4-0EFFD2CF65A6"><img alt="Getriebebau NORD GmbH &amp; Co. KG Logo" border="0" vspace="5" src="http://as-interface.net/Company/Logo/GN?MaxWidth=180&amp;MaxHeight=110&amp;Format=PNG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Contact:</h3><a href="http://as-interface.net/EN/Contact/542EE4A7-32BF-41E3-B98D-0E674D88E1F1">Mr. Torsten Bänsch </a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Category:</h3><a href="http://as-interface.net/EN/Products/Innovations/List/ACT">Actuators</a><br />Electric Actuators<br /><br /><img alt="GNSK200E" border="0" vspace="5" src="http://as-interface.net/DataMatrix/GNSK200E?Size=4"></img></td><td style="padding-left:15px"><h2 class="NoMargin" style="font-family: verdana;font-size: 8pt;color: #000000;font-weight: bold;background-color: #dedede;margin-top: 0px;padding:4px;padding-left:7px;margin-bottom: 9px;margin-left: 0px;margin-right: 0px;text-decoration: none;">Inverter SK 225E / SK 235E</h2>SK 200E motor-mounted frequency inverters offer increased flexibility for decentralised control <h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Certification by:</h3>AS-International Association<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Certification No:</h3>86501<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Description:</h3>The SK 200E for decentralised variety with a system

After long years of experience in the field of motor-mounted frequency inverters, with the SK 200E NORD has launched a new series of devices, which enable a wide spectrum of solutions for decentralised drive technology.

Following several years of experience in the design and manufacture of motor-mounted frequency inverters, NORD has launched its SK 200E series which enable a wide spectrum of solutions for decentralised drive technology.

The new SK 200E frequency inverter series is designed to be mounted directly on the motor terminal box to create a combined,  and fully integrated unit for use in the field. Similar to the SK 500E inverter series for control cabinet installation, which was launched two years ago, the new models provide a continuous range of performance and various a wide selection of optional features,  which that greatly simplify the selection of models to suit the particular application.

SK 225E/SK 235E
The new SK 225E and SK 235E models are available with outputs from 0.25 to 7.5 kW. The inverters are designed for direct mounting on the motor terminal box, in order to create combined,  and fully integrated drive units for use in the field. For AS-i wiring, only the yellow bus cable needs to be connected. These robust, reliable and economic systems are suitable for extensive large plant installations, e.g. conveyors, and were are specially optimised for price-sensitive market segments. 

The decentralised inverters offer sensorless current vector control and include four digital inputs and a switching unit for an electromagnetic brake. Thanks to the plug-in EEPROM module, they can simply and rapidly exchange parameter settings with units of the same type. With their practical range of accessories equipment, which also includes incremental encoder evaluation and integrated POSICON positioning control, the drives can cater for a wide range of applications. LEDs display the status information directly on the device.

The SK 235E can also be equipped with the safety function “Safe Stop” in compliance with EN 954-1 or EN 13849-1 (up to the maximum safety category 4, Stop category 0 and 1) to protect the connected motor against restarting  without switching off the power.
<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Specification:</h3>V3.0<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Product Link:</h3><a href="http://www.SK200E.de" target="_blank" alt="http://www.SK200E.de">www.SK200E.de</a></td></tr></table>]]></description><category>Innovations</category><link>http://as-interface.net/EN/Products/Innovations/3EBA6B1D-A702-42FA-8545-40F2046A26D7</link><guid isPermaLink="true">http://as-interface.net/EN/Products/Innovations/3EBA6B1D-A702-42FA-8545-40F2046A26D7</guid><dc:date>2012-04-02T14:58:14.173</dc:date><pubDate>2012-04-02T14:58:14.173</pubDate><author>Getriebebau NORD GmbH &amp; Co. KG</author><dc:creator>Getriebebau NORD GmbH &amp; Co. KG</dc:creator></item><item><title>Smile 11EA As-i</title><description><![CDATA[<table border="0" width="100%" cellspacing="0" cellpadding="0" class="Std" style="margin-top: 8px;font-size:8pt" xmlns="http://www.w3.org/1999/xhtml"><tr valign="top"><td><a href="http://as-interface.net/EN/Products/Image/86730B66-1BA3-4C94-9BCB-3806660C4E56"><img alt="Smile 11EA As-i Emergency stop with safe AS-i input slave" border="1" src="http://as-interface.net/Products/Image/86730B66-1BA3-4C94-9BCB-3806660C4E56?MaxWidth=250&amp;MaxHeight=360&amp;Format=JPG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Manufacturer:</h3><a href="http://as-interface.net/EN/Branch/1FBA41D3-3F23-41C9-B513-4E599C9FB30E"><img alt="ABB AB Logo" border="0" vspace="5" src="http://as-interface.net/Company/Logo/JS?MaxWidth=180&amp;MaxHeight=110&amp;Format=PNG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Contact:</h3><a href="http://as-interface.net/EN/Contact/80D75834-4AAF-428E-A5CF-35D9BCC29726">Mr. Anders Ingvarsson </a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Category:</h3><a href="http://as-interface.net/EN/Products/Innovations/List/SAFTY">Safety At Work</a><br />Emergency Stop / Command Device</td><td style="padding-left:15px"><h2 class="NoMargin" style="font-family: verdana;font-size: 8pt;color: #000000;font-weight: bold;background-color: #dedede;margin-top: 0px;padding:4px;padding-left:7px;margin-bottom: 9px;margin-left: 0px;margin-right: 0px;text-decoration: none;">Smile 11EA As-i</h2><a href="http://as-interface.net/EN/System/Safety"><img src="http://as-interface.net/Images/SaWSmall.gif" align="right" alt="Safety at Work Product" border="0"></img></a>Emergency stop with safe AS-i input slave<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Order No.:</h3>30-052-00<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Certification by:</h3>TÜV Nord (AS-i), Inspecta (emergency stop)<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Description:</h3>Smile 11EA AS-i is an emergency stop with a built-in dual channel safe AS-i input node.<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Specification:</h3>V3.0<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Product Link:</h3><a href="http://www.jokabsafety.com/assets/jokab/archive/documents/safety%20handbook/11_emergency_stops/11%20E-stop%202011-EN.pdf" target="_blank" alt="http://www.jokabsafety.com/assets/jokab/archive/documents/safety%20handbook/11_emergency_stops/11%20E-stop%202011-EN.pdf">www.jokabsafety.com/assets/jokab/archive/documents…</a></td></tr></table>]]></description><category>Innovations</category><link>http://as-interface.net/EN/Products/Innovations/86730B66-1BA3-4C94-9BCB-3806660C4E56</link><guid isPermaLink="true">http://as-interface.net/EN/Products/Innovations/86730B66-1BA3-4C94-9BCB-3806660C4E56</guid><dc:date>2011-12-21T15:32:19.503</dc:date><pubDate>2011-12-21T15:32:19.503</pubDate><author>ABB AB</author><dc:creator>ABB AB</dc:creator></item><item><title>Module for Building Management Systems</title><description><![CDATA[<table border="0" width="100%" cellspacing="0" cellpadding="0" class="Std" style="margin-top: 8px;font-size:8pt" xmlns="http://www.w3.org/1999/xhtml"><tr valign="top"><td><a href="http://as-interface.net/EN/Products/Image/A443F28D-BE71-4D06-8F96-B54D1C18A53F"><img alt="Module for Building Management Systems PB051" border="1" src="http://as-interface.net/Products/Image/A443F28D-BE71-4D06-8F96-B54D1C18A53F?MaxWidth=250&amp;MaxHeight=360&amp;Format=JPG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Manufacturer:</h3><a href="http://as-interface.net/EN/Branch/A9C87ECA-427E-49BF-AF2D-0A851E6872B8"><img alt="ICS Industrial Communication Solutions GmbH Logo" border="0" vspace="5" src="http://as-interface.net/Company/Logo/IC?MaxWidth=180&amp;MaxHeight=110&amp;Format=PNG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Contact:</h3><a href="http://as-interface.net/EN/Contact/D49F2990-E1DE-49D3-B808-0303E746BF1F">Mr. Andreas Schiff </a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Category:</h3><a href="http://as-interface.net/EN/Products/Innovations/List/MODS">Modules</a><br />Input / Output modules<br /><br /><img alt="ICPB051" border="0" vspace="5" src="http://as-interface.net/DataMatrix/ICPB051?Size=4"></img></td><td style="padding-left:15px"><h2 class="NoMargin" style="font-family: verdana;font-size: 8pt;color: #000000;font-weight: bold;background-color: #dedede;margin-top: 0px;padding:4px;padding-left:7px;margin-bottom: 9px;margin-left: 0px;margin-right: 0px;text-decoration: none;">Module for Building Management Systems</h2>PB051<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Order No.:</h3>PB051<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Description:</h3>Module for in-wall mounting with 2 inputs and 2 relay outputs for direct control of 230V AC roller blind motors.<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Specification:</h3>V3.0<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Documents:</h3><p><a href="/Products/Datasheet/A443F28D-BE71-4D06-8F96-B54D1C18A53F" title="Datasheet.pdf"><img src="/Images/DocTypes/pdfdoc.gif" width="16" height="16" align="absmiddle" border="0" hspace="3" vspace="1" alt="PDF" />Datasheet.pdf</a></p></td></tr></table>]]></description><category>Innovations</category><link>http://as-interface.net/EN/Products/Innovations/A443F28D-BE71-4D06-8F96-B54D1C18A53F</link><guid isPermaLink="true">http://as-interface.net/EN/Products/Innovations/A443F28D-BE71-4D06-8F96-B54D1C18A53F</guid><dc:date>2011-12-11T14:59:38.123</dc:date><pubDate>2011-12-11T14:59:38.123</pubDate><author>ICS Industrial Communication Solutions GmbH</author><dc:creator>ICS Industrial Communication Solutions GmbH</dc:creator></item><item><title>AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor and safe cross communication over Ethernet diagnostics interface</title><description><![CDATA[<table border="0" width="100%" cellspacing="0" cellpadding="0" class="Std" style="margin-top: 8px;font-size:8pt" xmlns="http://www.w3.org/1999/xhtml"><tr valign="top"><td><a href="http://as-interface.net/EN/Products/Image/AF895A75-BDC6-46A7-8D5F-47307C42A21C"><img alt="AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor and safe cross communication over Ethernet diagnostics interface " border="1" src="http://as-interface.net/Products/Image/AF895A75-BDC6-46A7-8D5F-47307C42A21C?MaxWidth=250&amp;MaxHeight=360&amp;Format=JPG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Manufacturer:</h3><a href="http://as-interface.net/EN/Branch/2B7379AA-B7C8-4ABE-AEE0-1124B689F00B"><img alt="Bihl + Wiedemann GmbH Logo" border="0" vspace="5" src="http://as-interface.net/Company/Logo/BW?MaxWidth=180&amp;MaxHeight=110&amp;Format=PNG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Contact:</h3><a href="http://as-interface.net/EN/Contact/254F5057-5A74-46B9-847E-6478490ADDE9">Mr. Fabricio Granados </a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Category:</h3><a href="http://as-interface.net/EN/Products/Innovations/List/SAFTY">Safety At Work</a><br />Safety Monitor / Safety PLC</td><td style="padding-left:15px"><h2 class="NoMargin" style="font-family: verdana;font-size: 8pt;color: #000000;font-weight: bold;background-color: #dedede;margin-top: 0px;padding:4px;padding-left:7px;margin-bottom: 9px;margin-left: 0px;margin-right: 0px;text-decoration: none;">AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor and safe cross communication over Ethernet diagnostics interface</h2><a href="http://as-interface.net/EN/System/Safety"><img src="http://as-interface.net/Images/SaWSmall.gif" align="right" alt="Safety at Work Product" border="0"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Order No.:</h3>BWu2602<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Description:</h3>2 AS-i 3.0 Master, PROFIBUS-Slave:<br>
Version "1 gateway + 1 power supply + 1 Safety Monitor for 2 AS-i networks"<br>
Full functional range of Bihl+Wiedemann PROFIBUS-Gateways BWU1569!<br>
Enhanced functional range of Bihl+Wiedemann Safety Monitor BWU2000!<br>
Compatible with the wide range of Bihl+Wiedemann power supplies<br><br><br>

1 AS-i Safety Monitor in Stainless Steel for 2 AS-i networks: <br>
Operation using a single Monitor configuration:<br>
-Monitor processes safety slaves on two AS-i networks<br>
-Coupling between the two networks superfluous<br><br>

16 release circuits: 4 CAT4, SIL3 safe output circuits on the Monitor:<br>
-two sets of safe relays<br>
-two sets of fast electronic safe outputs<br><br>

Safe AS-i outputs are supported on both AS-i networks:<br>
16 independent AS-i outputs<br>
Multiple safe AS-i outputs possible via a single AS-i address <br><br>

Monitor configuration can be ,arbitrarily" large<br>
256 configuration blocks (previously 48)<br>
Identical reaction time due to artificial limitation to 256 configuration blocks<br><br>

Chip card for storage of configuration data<br><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Special Features:</h3>Safe cross communication over Ethernet diagnostics interface: <br>
    Collect and evaluate up to 1922 safe AS-i Slaves<br>

    Central or decentralized control of safe outputs<br>

    Simple project planning<br>

    Couple up to 31 Safety Gateways
<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Documents:</h3><p><a href="/Products/Datasheet/AF895A75-BDC6-46A7-8D5F-47307C42A21C" title="Datasheet.pdf"><img src="/Images/DocTypes/pdfdoc.gif" width="16" height="16" align="absmiddle" border="0" hspace="3" vspace="1" alt="PDF" />Datasheet.pdf</a></p></td></tr></table>]]></description><category>Innovations</category><link>http://as-interface.net/EN/Products/Innovations/AF895A75-BDC6-46A7-8D5F-47307C42A21C</link><guid isPermaLink="true">http://as-interface.net/EN/Products/Innovations/AF895A75-BDC6-46A7-8D5F-47307C42A21C</guid><dc:date>2011-12-09T16:48:39.797</dc:date><pubDate>2011-12-09T16:48:39.797</pubDate><author>Bihl + Wiedemann GmbH</author><dc:creator>Bihl + Wiedemann GmbH</dc:creator></item><item><title>SISTO-SK-i AS-i</title><description><![CDATA[<table border="0" width="100%" cellspacing="0" cellpadding="0" class="Std" style="margin-top: 8px;font-size:8pt" xmlns="http://www.w3.org/1999/xhtml"><tr valign="top"><td><a href="http://as-interface.net/EN/Products/Image/0ED07B8B-26A4-49C4-A854-0299B3BBB4CA"><img alt="SISTO-SK-i AS-i Open / Close control and signalisation for linear pneumatic actuators" border="1" src="http://as-interface.net/Products/Image/0ED07B8B-26A4-49C4-A854-0299B3BBB4CA?MaxWidth=250&amp;MaxHeight=360&amp;Format=JPG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Manufacturer:</h3><a href="http://as-interface.net/EN/Branch/A8EB82FE-9219-40DF-B9A2-D037233890C7"><img alt="SISTO Armaturen S.A. Logo" border="0" vspace="5" src="http://as-interface.net/Company/Logo/KS?MaxWidth=180&amp;MaxHeight=110&amp;Format=PNG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Contact:</h3><a href="http://as-interface.net/EN/Contact/691A8D6E-4724-4679-9E03-9E901C632BC4">Mr. Alfred Knoebl </a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Category:</h3><a href="http://as-interface.net/EN/Products/Innovations/List/ACT">Actuators</a><br />Pneumatic Actuators</td><td style="padding-left:15px"><h2 class="NoMargin" style="font-family: verdana;font-size: 8pt;color: #000000;font-weight: bold;background-color: #dedede;margin-top: 0px;padding:4px;padding-left:7px;margin-bottom: 9px;margin-left: 0px;margin-right: 0px;text-decoration: none;">SISTO-SK-i AS-i</h2>Open / Close control and signalisation for linear pneumatic actuators<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Description:</h3><p>SISTO-SK-i is an intelligent Position Indicator for linear actuated valves with integrated optical position feedback by coloured LED's.</p>

<p>Easy on-site programming can be performed over 2 push buttons or by process control system.</p><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Specification:</h3>V3.0<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Special Features:</h3><li type="square">Easy on site programming over 2 push buttons
<li type="square">External programming input
<li type="square">Available with full stainless steel housing<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Documents:</h3><p><a href="/Products/Datasheet/0ED07B8B-26A4-49C4-A854-0299B3BBB4CA" title="Datasheet.pdf"><img src="/Images/DocTypes/pdfdoc.gif" width="16" height="16" align="absmiddle" border="0" hspace="3" vspace="1" alt="PDF" />Datasheet.pdf</a></p></td></tr></table>]]></description><category>Innovations</category><link>http://as-interface.net/EN/Products/Innovations/0ED07B8B-26A4-49C4-A854-0299B3BBB4CA</link><guid isPermaLink="true">http://as-interface.net/EN/Products/Innovations/0ED07B8B-26A4-49C4-A854-0299B3BBB4CA</guid><dc:date>2011-11-24T13:53:23.787</dc:date><pubDate>2011-11-24T13:53:23.787</pubDate><author>SISTO Armaturen S.A.</author><dc:creator>SISTO Armaturen S.A.</dc:creator></item><item><title>I/O slave module</title><description><![CDATA[<table border="0" width="100%" cellspacing="0" cellpadding="0" class="Std" style="margin-top: 8px;font-size:8pt" xmlns="http://www.w3.org/1999/xhtml"><tr valign="top"><td><a href="http://as-interface.net/EN/Products/Image/EB3D8366-1065-4265-BD01-AA714F4879C7"><img alt="I/O slave module Switching output" border="1" src="http://as-interface.net/Products/Image/EB3D8366-1065-4265-BD01-AA714F4879C7?MaxWidth=250&amp;MaxHeight=360&amp;Format=JPG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Manufacturer:</h3><a href="http://as-interface.net/EN/Branch/867FEFD6-717D-4F56-8908-6B28E241D94A"><img alt="EMA Electronic Corp. Logo" border="0" vspace="5" src="http://as-interface.net/Company/Logo/EM?MaxWidth=180&amp;MaxHeight=110&amp;Format=PNG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Contact:</h3><a href="http://as-interface.net/EN/Contact/207758A9-2C0B-4C20-B8EA-C7F2D69DDA62">Ms. Judy Chen </a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Category:</h3><a href="http://as-interface.net/EN/Products/Innovations/List/MODS">Modules</a><br />Input / Output modules</td><td style="padding-left:15px"><h2 class="NoMargin" style="font-family: verdana;font-size: 8pt;color: #000000;font-weight: bold;background-color: #dedede;margin-top: 0px;padding:4px;padding-left:7px;margin-bottom: 9px;margin-left: 0px;margin-right: 0px;text-decoration: none;">I/O slave module</h2>Switching output<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Order No.:</h3>AS4104<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Description:</h3>- signal process by special coding can be transmitted by power cable,and it can reduce the time spending on wiring in field and on detection
- Lower cost of wiring,design,and maintenance 
- Apply to satellite ,tree,and cyclic wiring system
- Protection classification:IP67
- Operating voltage:26.5...31.6VDC
- Voltage range:18...30VDC 
<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Product Link:</h3><a href="http://www.ema-electronic.com/product_en.asp?anclass=35" target="_blank" alt="http://www.ema-electronic.com/product_en.asp?anclass=35">www.ema-electronic.com/product_en.asp?anclass=35</a></td></tr></table>]]></description><category>Innovations</category><link>http://as-interface.net/EN/Products/Innovations/EB3D8366-1065-4265-BD01-AA714F4879C7</link><guid isPermaLink="true">http://as-interface.net/EN/Products/Innovations/EB3D8366-1065-4265-BD01-AA714F4879C7</guid><dc:date>2011-11-16T09:02:34.413</dc:date><pubDate>2011-11-16T09:02:34.413</pubDate><author>EMA Electronic Corp.</author><dc:creator>EMA Electronic Corp.</dc:creator></item><item><title>Interroll Frequency Inverter IFI-IP55</title><description><![CDATA[<table border="0" width="100%" cellspacing="0" cellpadding="0" class="Std" style="margin-top: 8px;font-size:8pt" xmlns="http://www.w3.org/1999/xhtml"><tr valign="top"><td><a href="http://as-interface.net/EN/Products/Image/ABE10C0A-06A1-4295-9405-81B0A064F933"><img alt="Interroll Frequency Inverter IFI-IP55 " border="1" src="http://as-interface.net/Products/Image/ABE10C0A-06A1-4295-9405-81B0A064F933?MaxWidth=250&amp;MaxHeight=360&amp;Format=JPG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Manufacturer:</h3><a href="http://as-interface.net/EN/Branch/CA4F7DAA-2BC2-48F2-8815-A57FD50D651D"><img alt="INTERROLL (SCHWEIZ) A G Logo" border="0" vspace="5" src="http://as-interface.net/Company/Logo/IR?MaxWidth=180&amp;MaxHeight=110&amp;Format=PNG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Contact:</h3><a href="http://as-interface.net/EN/Contact/F19A94EF-1744-4A9B-823B-BC404D445A3B">Mr. Lorenz Köhler </a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Category:</h3><a href="http://as-interface.net/EN/Products/Innovations/List/ACT">Actuators</a><br />Electric Actuators</td><td style="padding-left:15px"><h2 class="NoMargin" style="font-family: verdana;font-size: 8pt;color: #000000;font-weight: bold;background-color: #dedede;margin-top: 0px;padding:4px;padding-left:7px;margin-bottom: 9px;margin-left: 0px;margin-right: 0px;text-decoration: none;">Interroll Frequency Inverter IFI-IP55</h2><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Description:</h3>The IFI-IP55 is  Interroll's  sensor-less frequency inverter drive for asynchronous and synchronous drum motors. The decentralized IFI Driver meets all user requirements: compact design with easy-to-use connectors for fast and simple installation. This product is the perfect Driver to control speed of the high efficient synchronous Drum Motor series. The As-Interface offers a full integration of the Driver to the factory automation. <h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Specification:</h3>V3.0<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Special Features:</h3>Functions

    * Decentralized IP55 Unit
    * Sensorless
    * AS-Interface
    * Fully programmable via Modbus Communication Port or Opti-Pad
    * M23 Plug Connectors for Power Supply
    * LED status display
    * 2 Digital Inputs
<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Product Link:</h3><a href="http://interroll.com/en/products/drum_motors/drives_and_controls/ifi-ip55/" target="_blank" alt="http://interroll.com/en/products/drum_motors/drives_and_controls/ifi-ip55/">interroll.com/en/products/drum_motors/drives_and_c…</a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Documents:</h3><p><a href="/Products/Datasheet/ABE10C0A-06A1-4295-9405-81B0A064F933" title="Datasheet.pdf"><img src="/Images/DocTypes/pdfdoc.gif" width="16" height="16" align="absmiddle" border="0" hspace="3" vspace="1" alt="PDF" />Datasheet.pdf</a></p><p><a href="/Products/Brochure/ABE10C0A-06A1-4295-9405-81B0A064F933" title="Brochure.pdf"><img src="/Images/DocTypes/pdfdoc.gif" width="16" height="16" align="absmiddle" border="0" hspace="3" vspace="1" alt="PDF" />Brochure.pdf</a></p></td></tr></table>]]></description><category>Innovations</category><link>http://as-interface.net/EN/Products/Innovations/ABE10C0A-06A1-4295-9405-81B0A064F933</link><guid isPermaLink="true">http://as-interface.net/EN/Products/Innovations/ABE10C0A-06A1-4295-9405-81B0A064F933</guid><dc:date>2011-09-09T11:08:11.373</dc:date><pubDate>2011-09-09T11:08:11.373</pubDate><author>INTERROLL (SCHWEIZ) A G</author><dc:creator>INTERROLL (SCHWEIZ) A G</dc:creator></item><item><title>BDF 200 AS / Control panel with E-STOP function</title><description><![CDATA[<table border="0" width="100%" cellspacing="0" cellpadding="0" class="Std" style="margin-top: 8px;font-size:8pt" xmlns="http://www.w3.org/1999/xhtml"><tr valign="top"><td><a href="http://as-interface.net/EN/Products/Image/DB06EDD3-8C7B-41E9-ABCC-CF08B4934704"><img alt="BDF 200 AS / Control panel with E-STOP function " border="1" src="http://as-interface.net/Products/Image/DB06EDD3-8C7B-41E9-ABCC-CF08B4934704?MaxWidth=250&amp;MaxHeight=360&amp;Format=JPG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Manufacturer:</h3><a href="http://as-interface.net/EN/Branch/11E6986E-E13B-4101-B0A0-08927413002C"><img alt="K. A. SCHMERSAL GmbH Logo" border="0" vspace="5" src="http://as-interface.net/Company/Logo/SH?MaxWidth=180&amp;MaxHeight=110&amp;Format=PNG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Contact:</h3><a href="http://as-interface.net/EN/Contact/38A98A57-8E18-4244-A01E-0919E8ACD321">Mr. Udo Weber </a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Category:</h3><a href="http://as-interface.net/EN/Products/Innovations/List/SAFTY">Safety At Work</a><br />Emergency Stop / Command Device</td><td style="padding-left:15px"><h2 class="NoMargin" style="font-family: verdana;font-size: 8pt;color: #000000;font-weight: bold;background-color: #dedede;margin-top: 0px;padding:4px;padding-left:7px;margin-bottom: 9px;margin-left: 0px;margin-right: 0px;text-decoration: none;">BDF 200 AS / Control panel with E-STOP function</h2><a href="http://as-interface.net/EN/System/Safety"><img src="http://as-interface.net/Images/SaWSmall.gif" align="right" alt="Safety at Work Product" border="0"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Description:</h3>Control panel with E-STOP function and integrated AS-I interface <p>
• E-STOP, start/stop and reset function available <p>
• comprehensive selection of illuminated pushbuttons, selector switches, LED signalling devices and E-STOP pushbuttons <p>
• integrated Safety-Slave for E-STOP <p>
• integrated A/B-Slave for command and signalling devices <p>
• optional with indicator lamp G24, top <p>
• E-STOP up to control category 4 / PL e / SIL 3 <p>
• M12 connector for AS-Interface <p>
• thermoplastic enclosure <p>
• protection class IP 65<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Specification:</h3>V3.0<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Product Link:</h3><a href="http://www.schmersal.net/cat?&amp;produkt=wk9734218cu1iv6fcza46350svf9jb" target="_blank" alt="http://www.schmersal.net/cat?&amp;produkt=wk9734218cu1iv6fcza46350svf9jb">www.schmersal.net/cat?&amp;produkt=wk9734218cu1iv6fcza…</a></td></tr></table>]]></description><category>Innovations</category><link>http://as-interface.net/EN/Products/Innovations/DB06EDD3-8C7B-41E9-ABCC-CF08B4934704</link><guid isPermaLink="true">http://as-interface.net/EN/Products/Innovations/DB06EDD3-8C7B-41E9-ABCC-CF08B4934704</guid><dc:date>2011-08-18T14:06:17.32</dc:date><pubDate>2011-08-18T14:06:17.32</pubDate><author>K. A. SCHMERSAL GmbH</author><dc:creator>K. A. SCHMERSAL GmbH</dc:creator></item><item><title>BI2 - ASI</title><description><![CDATA[<table border="0" width="100%" cellspacing="0" cellpadding="0" class="Std" style="margin-top: 8px;font-size:8pt" xmlns="http://www.w3.org/1999/xhtml"><tr valign="top"><td><a href="http://as-interface.net/EN/Products/Image/C7AC0CD7-E959-4DA6-B901-EDC000179CF3"><img alt="BI2 - ASI ASI - BI2" border="1" src="http://as-interface.net/Products/Image/C7AC0CD7-E959-4DA6-B901-EDC000179CF3?MaxWidth=250&amp;MaxHeight=360&amp;Format=JPG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Manufacturer:</h3><a href="http://as-interface.net/EN/Branch/021BDDCC-2454-4A47-842B-0E5198F63E3F"><img alt="Bernstein AG Logo" border="0" vspace="5" src="http://as-interface.net/Company/Logo/BS?MaxWidth=180&amp;MaxHeight=110&amp;Format=PNG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Contact:</h3><a href="http://as-interface.net/EN/Contact/78CE1C74-4BBF-4BE4-978F-7C4F15E4AA93">Mr. Marcus Scholz </a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Category:</h3><a href="http://as-interface.net/EN/Products/Innovations/List/SAFTY">Safety At Work</a><br />Emergency Stop / Command Device</td><td style="padding-left:15px"><h2 class="NoMargin" style="font-family: verdana;font-size: 8pt;color: #000000;font-weight: bold;background-color: #dedede;margin-top: 0px;padding:4px;padding-left:7px;margin-bottom: 9px;margin-left: 0px;margin-right: 0px;text-decoration: none;">BI2 - ASI</h2><a href="http://as-interface.net/EN/System/Safety"><img src="http://as-interface.net/Images/SaWSmall.gif" align="right" alt="Safety at Work Product" border="0"></img></a>ASI - BI2<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Order No.:</h3>6073201052<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Description:</h3>The ASI BI2 is a common standard switch. The enclosure and cover are made of glass fibre reinforced Thermoplastic. The cover is provided with LEDs that show status of ASI-Slave and busses. Because of the side connection device and the low enlosure level of the ASI BI2 this safety switch is especially suitable for thight installation areas. The 4 mounting possibilities additionally increase the assembly-friendliness. Protection type IP65 according to EN 60529 and DIN VDE 0470 T1 can be guaranteed.</td></tr></table>]]></description><category>Innovations</category><link>http://as-interface.net/EN/Products/Innovations/C7AC0CD7-E959-4DA6-B901-EDC000179CF3</link><guid isPermaLink="true">http://as-interface.net/EN/Products/Innovations/C7AC0CD7-E959-4DA6-B901-EDC000179CF3</guid><dc:date>2011-07-19T13:43:39.027</dc:date><pubDate>2011-07-19T13:43:39.027</pubDate><author>Bernstein AG</author><dc:creator>Bernstein AG</dc:creator></item><item><title>The world's smallest AS-i module G10</title><description><![CDATA[<table border="0" width="100%" cellspacing="0" cellpadding="0" class="Std" style="margin-top: 8px;font-size:8pt" xmlns="http://www.w3.org/1999/xhtml"><tr valign="top"><td><a href="http://as-interface.net/EN/Products/Image/6AD4F7A5-0BD7-4379-9DF4-C2D5578902B3"><img alt="The world's smallest AS-i module G10 VBA-2E1A-G10-ZAL/E2L-1M-2V1-W" border="1" src="http://as-interface.net/Products/Image/6AD4F7A5-0BD7-4379-9DF4-C2D5578902B3?MaxWidth=250&amp;MaxHeight=360&amp;Format=JPG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Manufacturer:</h3><a href="http://as-interface.net/EN/Branch/1B033163-75F7-4201-A2DF-028985AAC9A7"><img alt="Pepperl + Fuchs GmbH Logo" border="0" vspace="5" src="http://as-interface.net/Company/Logo/PF?MaxWidth=180&amp;MaxHeight=110&amp;Format=PNG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Contact:</h3><a href="http://as-interface.net/EN/Contact/C19318CD-7B88-4B5C-818C-CEBC7A565FA3">Mr. Konrad Kern </a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Category:</h3><a href="http://as-interface.net/EN/Products/Innovations/List/MODS">Modules</a><br />Input / Output modules<br /><br /><img alt="PFULTRAKOMPAKTMODUL" border="0" vspace="5" src="http://as-interface.net/DataMatrix/PFULTRAKOMPAKTMODUL?Size=4"></img></td><td style="padding-left:15px"><h2 class="NoMargin" style="font-family: verdana;font-size: 8pt;color: #000000;font-weight: bold;background-color: #dedede;margin-top: 0px;padding:4px;padding-left:7px;margin-bottom: 9px;margin-left: 0px;margin-right: 0px;text-decoration: none;">The world's smallest AS-i module G10</h2>VBA-2E1A-G10-ZAL/E2L-1M-2V1-W<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Order No.:</h3>VBA-2E1A-G10-ZAL/E2L-1M-2V1-W<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Description:</h3>The AS-Interface G10 ultra-compact I/O module is a perfect I/O solution for installation in cable trays and highly decentralized installations. The ultra-compact G10 from Pepperl+Fuchs is the world’s smallest AS-Interface I/O module with IP68/69K protection.  With a footprint of just above 1 inch2 per I/O, this exceptionally compact module defines the new state-of-the-art and allows mounting in the most space-confined applications.  In fact, simply placing the G10 inside the cable tray may eliminate mounting entirely.  Only the integrated pigtail cordsets for sensors and actuators are located outside of the cable tray; the AS-Interface flat cable remains in the cable tray at all times, eliminating additional mounting steps altogether.  Due to the pigtail solution the G10 modules do not require additional cordsets, and any conventional sensor is quickly converted into a convenient, efficient AS-Interface solution.
<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Specification:</h3>V3.0<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Special Features:</h3>The single piece housing makes use of a patented hinged cover, a design with a proven track record also used on the Pepperl+Fuchs’ line of passive splitters. When mounting is required, it’s fast and easy; only one screw is needed to reliably mount the G10. There are no gaskets, inserts, separate housing parts, or additional screws that are easily lost.  
As on all other AS-Interface modules, Pepperl+Fuchs  uses high-quality, machined, gold-plated piercing contacts that, unlike the cheap stamped and zinc-coated alternative, provide superior long-term contact stability without damaging the internal strands of the AS-Interface cable.  Placed around each of the piercing contacts is a concentric seal contour providing high seal contact pressure, a main contributor to the reliable IP68/69K protection, even after many years of service.
Power to the sensors is supplied from AS-Interface or AUX power, and a continuous output current of up to 1 A can be supplied.  There are three versions of the G10 and each is equipped with diagnostic and status LEDs, follows the latest AS-Interface specification 3.0, and already supports AS-Interface Power24 
<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Product Link:</h3><a href="http://www.pepperl-fuchs.de/cps/rde/xchg/germany/hs.xsl/goto-selector.htm/papp/Selektor/selector/gui/start_selector.kly?lang=DEU" target="_blank" alt="http://www.pepperl-fuchs.de/cps/rde/xchg/germany/hs.xsl/goto-selector.htm/papp/Selektor/selector/gui/start_selector.kly?lang=DEU">www.pepperl-fuchs.de/cps/rde/xchg/germany/hs.xsl/g…</a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Documents:</h3><p><a href="/Products/Datasheet/6AD4F7A5-0BD7-4379-9DF4-C2D5578902B3" title="Datasheet.pdf"><img src="/Images/DocTypes/pdfdoc.gif" width="16" height="16" align="absmiddle" border="0" hspace="3" vspace="1" alt="PDF" />Datasheet.pdf</a></p><p><a href="/Products/Brochure/6AD4F7A5-0BD7-4379-9DF4-C2D5578902B3" title="Brochure.pdf"><img src="/Images/DocTypes/pdfdoc.gif" width="16" height="16" align="absmiddle" border="0" hspace="3" vspace="1" alt="PDF" />Brochure.pdf</a></p></td></tr></table>]]></description><category>Innovations</category><link>http://as-interface.net/EN/Products/Innovations/6AD4F7A5-0BD7-4379-9DF4-C2D5578902B3</link><guid isPermaLink="true">http://as-interface.net/EN/Products/Innovations/6AD4F7A5-0BD7-4379-9DF4-C2D5578902B3</guid><dc:date>2011-02-25T16:27:56.863</dc:date><pubDate>2011-02-25T16:27:56.863</pubDate><author>Pepperl + Fuchs GmbH</author><dc:creator>Pepperl + Fuchs GmbH</dc:creator></item><item><title>eC/DC 300-R</title><description><![CDATA[<table border="0" width="100%" cellspacing="0" cellpadding="0" class="Std" style="margin-top: 8px;font-size:8pt" xmlns="http://www.w3.org/1999/xhtml"><tr valign="top"><td><a href="http://as-interface.net/EN/Products/Image/625AD4C2-AB03-49C6-B227-E0CA4E36B1CD"><img alt="eC/DC 300-R " border="1" src="http://as-interface.net/Products/Image/625AD4C2-AB03-49C6-B227-E0CA4E36B1CD?MaxWidth=250&amp;MaxHeight=360&amp;Format=JPG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Manufacturer:</h3><a href="http://as-interface.net/EN/Branch/F4A4BA13-3045-4BC0-8618-250C296B8757"><img alt="Würth Elektronik GmbH &amp; Co.KG Logo" border="0" vspace="5" src="http://as-interface.net/Company/Logo/WT?MaxWidth=180&amp;MaxHeight=110&amp;Format=PNG&amp;"></img></a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Contact:</h3><a href="http://as-interface.net/EN/Contact/9697AAAC-6D74-4C20-9EC9-558C908CF512">Mr. Anatol  Schwersenz </a><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Category:</h3><a href="http://as-interface.net/EN/Products/Innovations/List/ACC">Accessories and Other</a><br />Integrated Circuits</td><td style="padding-left:15px"><h2 class="NoMargin" style="font-family: verdana;font-size: 8pt;color: #000000;font-weight: bold;background-color: #dedede;margin-top: 0px;padding:4px;padding-left:7px;margin-bottom: 9px;margin-left: 0px;margin-right: 0px;text-decoration: none;">eC/DC 300-R</h2><h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Order No.:</h3>eC/DC 300-R<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Description:</h3>Überzeugen Sie sich selbst von den Vorteilen des eC/DC-Moduls*. Zu diesem Zweck haben wir das Evaluation Board eC/DC 300-R konzipiert. Es stellt ein 4In/4Out-Slavemodul dar, welches im erweiterten Adressmodus mittels ASI4U, mit Überstromschutz, Verpolschutz und optimalem Symmetrieverhalten über den gesamten Frequenzbereich ausgestattet ist. Das eC/DC-Modul ist einfach in Ihre AS-i Slave-Schaltung als fertiges 5-poliges Bauelement integrierbar.

<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Special Features:</h3>Die Vorteile auf einen Blick:?


Hohe Strombelastbarkeit bis zu 300 mA bzw. 600 mA 
-Geringe parasitäre Effekte 
-geringerer Spannungsabfall im Vergleich zu herkömmlichen Lösungen (ca. 20 %) 
-5-poliges Bauelement mit Verpolschutz (komplett bestückt und getestet) 
-Ready für Power 24 
-Unempfindlich gegen Stöße und Vibrationen
-Absolute Symmetrie über gesamten Frequenzbereich<h3 xml:lang="EN" style="font-size: 8pt;color: #3E5782;font-weight: bold;margin-top:12px;margin-bottom:0px;">Product Link:</h3><a href="http://www.wuerth-elektronik.de/web/de/cbt/more_than_you_expect_1/forschung_und_entwicklung/ecdc-modul/form_Best_eval_Board_FuE_" target="_blank" alt="http://www.wuerth-elektronik.de/web/de/cbt/more_than_you_expect_1/forschung_und_entwicklung/ecdc-modul/form_Best_eval_Board_FuE_">www.wuerth-elektronik.de/web/de/cbt/more_than_you_…</a></td></tr></table>]]></description><category>Innovations</category><link>http://as-interface.net/EN/Products/Innovations/625AD4C2-AB03-49C6-B227-E0CA4E36B1CD</link><guid isPermaLink="true">http://as-interface.net/EN/Products/Innovations/625AD4C2-AB03-49C6-B227-E0CA4E36B1CD</guid><dc:date>2011-02-04T18:06:07.167</dc:date><pubDate>2011-02-04T18:06:07.167</pubDate><author>Würth Elektronik GmbH &amp; Co.KG</author><dc:creator>Würth Elektronik GmbH &amp; Co.KG</dc:creator></item></channel></rss>